Retrieves and sets various settings of the current patch.
See control-panel and patch-editor-panel for more info.
Name or caption of the object as it appears in its visible interface.
Full path of the file the patch was loaded from or last saved to, empty if the patch has never been saved. It's a read only setting: it is not saved with the patch and can only be exposed as an outlet, not as an inlet.
Manual page about of this object.
show manual
Opens the default web browser the selected object and displays an html page.
Determines if parameters of this object are saved in the preset-panel of the rack.
Parameters of the this object can cross faded when you recall a preset in the grid.
Optional setting, does not appear on all objects.
When ON, this object will be randomized when using the randomize command.
When ON, this object will be reset to its default value when using the reset command of its patch.
Determines if the rack or the patch is automatically maximized when it's active on the grid and minimized when inactive.
Hint text displayed on mouse over.

Determines if parameters of this object are saved in the preset-panel.
Parameters of the this object can cross faded when you recall a preset in the grid.
Optional setting, does not appear on all objects.
Hint text displayed on mouse over.

Enables or disables the undo/redo history of the patch. Default ON. When OFF, Usine no longer stores an undo snapshot of the patch after each editing operation, and the undo and redo commands are refused with a warning message. This can speed up the patching interface on very heavy patches and avoids the saving after each operation. The setting is only available on normal patches (not on sub-patches or device patches) and the value of the main patch applies to all its sub-patches.
It's not recommended to disable it.
Enables the panel.
Minimizes or maximizes the panel.
Opens/closes the preset panel.
Reduce the size of the current object.
Only available on MIDI input device patches. When ON, the MIDI real-time messages received on this device drive the master synchro panel of Usine: timing clock messages set the tempo (measured every 48 clocks, ie. every 2 beats), a start message restarts the synchro from the beginning and switches it ON, a continue message switches it ON, a stop message switches it OFF and song position pointer messages re-synchronize the beat position inside the bar. When OFF, these messages are ignored.
Only available on MIDI output device patches. When ON and the device is active, Usine sends MIDI timing clock messages to this output device at the tempo of the master synchro panel (24 clocks per beat), plus a start message when the synchro is switched ON and a stop message when it is switched OFF, so that external devices can follow Usine's tempo. When OFF, no clock message is sent.
Only available on MIDI output device patches. When ON, Usine considers that the hardware attached to this MIDI output device is motorized (motor faders, LED rings, etc.): each time a control that is MIDI-learned on the input device of the same name changes in Usine, its new value is sent back to this output device so the hardware stays in sync. When OFF, no feedback is sent to this device, unless the global option MIDI feedback to all devices of the setup panel is ON.
Sends value if Usine is currently recalling a preset, 0 otherwise.
Current preset number.
Recalls the current preset number.
Outputs a list of all presets names as a comma-text.
Duration of the fade when recalling a preset (in seconds).
CPU load of the patch (in percent).
Current grid fade gain out for the patch.
Randomize all the patch parameters.
Sends 1 when randomizing the patch.
Reset all the patch parameters to their default value.
Sends 1 when resetting the patch.
Opens the patch edition window.
Minimizes the control-panel of the current patch.
Maximizes the control-panel of the current patch.
Toggles the minimized state of the control-panel of the current patch.
Reduces the control-panel of the current patch.
Enlarges the control-panel of the current patch.
Toggles the reduced state of the control-panel of the current patch.
Selects the control-panel of the current patch.
Current zoom scale of the patch.
When ON, the patch can be zoomed.
Left position of the control panel in pixels.
Top position of the control panel in pixels.
Width of the control panel in pixels.
Height of the control panel in pixels.
Horizontal position of the control panel (0..1).
Vertical position of the control panel (0..1).
Width of the control panel as a percentage.
Height of the control panel as a percentage.
When ON, the resize grip is enabled (global setting).
When ON, the left edge can be resized.
When ON, the right edge can be resized.
When ON, the top edge can be resized.
When ON, the bottom edge can be resized.
When ON, the control panel is minimized.
When ON, modules snap to the grid.
Size of the grid in pixels.
When ON, the control panel auto resizes to fit its content.
Margin in pixels for auto resize.
Forces the reorganization of the modules layout.
Location of the patch panel.
Global color applied to the patch.
When ON, this patch ignores the parent global color.
Name of the current snapshot.
When ON, the control panel is displayed on top of other panels.
Opacity of the control panel (0..1).
When ON, the control panel background is transparent.
Background color of the control panel.
Highlighted color of the control panel.
Background image file for the control panel.
Force the image file to adapt its displayed size to the size of the object.
When ON, the border is visible.
Color of the border.
Width of the border in pixels.
Corner rounding radius in pixels.
When ON, the selection border is not drawn.
When ON, the caption is visible.
Font color of the caption.
Font size scale factor of the caption.
Alignment of the caption text.
Font name for the caption.
When ON, the caption text is bold.
When ON, the caption text is italic.
When ON, the caption text is underlined.
When ON, the header bar is visible.
Height of the header bar in pixels.
Color of the header bar.
When ON, the header bar is filled with a solid color.
When ON, the toolbar is visible.
Size scale factor of the toolbar.
Number of modules in the patch (read only).
Number of wires in the patch (read only).
Number of quicklinks in the patch (read only).
Button. Opens the manual page of the selected object (or of its parent module for a control) in the web browser. If no page exists for this object, an error is traced in the trace panel.
For more details about information/help creation, see create-help-file.
Free multi-line text attached to the module, saved with the patch. It is only meant as an internal note for the patch designer: it is not displayed in the interface.
visible only in god mode, see setup-panel-tab-expert.
Read-only, not saved. Current private numeric ID of the object, used internally to identify it (for example as the target of a bind ID).
Read-only, not saved. Private ID used to store and recall the values of this control in presets.
Button. Generates a new unique ID, original ID and preset ID for the object. Use it if you experience difficulties in Polyphonic mode or if two objects share the same ID. Preset values and binds referring to the old IDs are lost.
Read-only, not saved. Absolute address of the object in the Usine objects tree, built from the workspace root. This is the address to use to reach the object from scripts, the objects panel or remote messages. Only shown for objects that are registered in the objects list. See objects-address.
Read-only, not saved. Address of the object relative to the current patch, valid inside that patch only. See objects-address.
Free user-defined address for the object (empty by default). When set, the object is also registered in the objects tree under this name, so it can be reached independently of its position in the workspace (the value is also reported in the mouse-over and mouse-down chunks). Changing it rebuilds the objects list. Only available on objects that support a user address. See objects-address.
Allows or not the horizontal scroller to be displayed at the bottom of the container. Default ON. When ON, the scroller appears automatically as soon as the content of the container is wider than the container itself and disappears when the content fits again; when OFF, it is never displayed and the content is scrolled back to its origin.
The scroller appears only if the container is smaller than the controls inside. It is also never displayed when the container is in auto size mode.
Example of horizontal scroller
Height of the scroller bar in pixels, from 0 to 100, default 14.
Color of the scroller thumb (the moving part whose length represents the visible portion of the content).
Background color of the scroller track. Default is fully transparent, so only the thumb is visible.
Opacity of the scroller, from 0.2 to 1, default 1.