Usine Master Light Settings

Provides a replica of the master-light-panel.

See master-light-panel for more info.

Settings

plot

Shows or hides the light plot panel.

panic

Sends a "light panic" to all connected light devices.

plot settings

sacn mode

Determines how the sACN (streaming ACN, E1.31 DMX over IP) packets of the plot are sent on the network. Available for each plot of the plot-panel.

  • unicast (default): packets are sent only to the device defined by the sACN unicast IP address.
  • multicast: packets are sent to the standard sACN multicast address 239.255.x.x, where x.x is the high and low byte of the universe number plus one (universe 0 = 239.255.0.1, universe 2 = 239.255.0.3, universe 512 = 239.255.2.1).
  • broadcast: packets are sent to all devices of the network, restricted by the sACN broadcast mask. Depending on the router this can slow down the network, use it only when a broadcast is really required.

Packets are sent only if send sACN is ON for the plot and the sACN protocol is activated in the setup-panel-tab-light.

Common Settings

info

show manual

Button. Opens the manual page of the selected object (or of its parent module for a control) in the web browser. If no page exists for this object, an error is traced in the trace panel.

For more details about information/help creation, see create-help-file.

description

Free multi-line text attached to the module, saved with the patch. It is only meant as an internal note for the patch designer: it is not displayed in the interface.

ID's

visible only in god mode, see setup-panel-tab-expert.

unique ID

Read-only, not saved. Current private numeric ID of the object, used internally to identify it (for example as the target of a bind ID).

preset ID

Read-only, not saved. Private ID used to store and recall the values of this control in presets.

recreate ID

Button. Generates a new unique ID, original ID and preset ID for the object. Use it if you experience difficulties in Polyphonic mode or if two objects share the same ID. Preset values and binds referring to the old IDs are lost.

Object Remote Address

absolute

Read-only, not saved. Absolute address of the object in the Usine objects tree, built from the workspace root. This is the address to use to reach the object from scripts, the objects panel or remote messages. Only shown for objects that are registered in the objects list. See objects-address.

local

Read-only, not saved. Address of the object relative to the current patch, valid inside that patch only. See objects-address.

user addr

Free user-defined address for the object (empty by default). When set, the object is also registered in the objects tree under this name, so it can be reached independently of its position in the workspace (the value is also reported in the mouse-over and mouse-down chunks). Changing it rebuilds the objects list. Only available on objects that support a user address. See objects-address.