Registers this device as a service using the MDNS no configuration protocol also called Bonjour.
Button to turn on or off the service.
A light that indicates whether the service is running. Because setting up and shutting down the service takes time, you may notice a small latency between clicking the on button and the running indicator light registering.
Most importantly if an error occurred during service start up (if you're not connected to any network for example), this light will not turn on.
The name of the host of this service, the intended usage is to use the Setup Settings module and its host name field to get the computer name.
The port the service is meant to listen on, this is not the MDNS port but the one that your traditional udp/tcp server or client is using.
The name of the provided service.
The network protocol used.
The domain of the service, should pretty much always be local.
Sends out a trigger when this service gets pinged (when a request for this specific service is received).
The IP address of the computer that last pinged this service.
Button. Opens the manual page of the selected object (or of its parent module for a control) in the web browser. If no page exists for this object, an error is traced in the trace panel.
For more details about information/help creation, see create-help-file.
Free multi-line text attached to the module, saved with the patch. It is only meant as an internal note for the patch designer: it is not displayed in the interface.
visible only in god mode, see setup-panel-tab-expert.
Read-only, not saved. Current private numeric ID of the object, used internally to identify it (for example as the target of a bind ID).
Read-only, not saved. Private ID used to store and recall the values of this control in presets.
Button. Generates a new unique ID, original ID and preset ID for the object. Use it if you experience difficulties in Polyphonic mode or if two objects share the same ID. Preset values and binds referring to the old IDs are lost.
Read-only, not saved. Absolute address of the object in the Usine objects tree, built from the workspace root. This is the address to use to reach the object from scripts, the objects panel or remote messages. Only shown for objects that are registered in the objects list. See objects-address.
Read-only, not saved. Address of the object relative to the current patch, valid inside that patch only. See objects-address.
Free user-defined address for the object (empty by default). When set, the object is also registered in the objects tree under this name, so it can be reached independently of its position in the workspace (the value is also reported in the mouse-over and mouse-down chunks). Changing it rebuilds the objects list. Only available on objects that support a user address. See objects-address.
version 7.0.250121