Bitwise MULT

Multiplies A by B using unsigned 32-bit integer arithmetic. Only the low 32 bits of the product are kept (the result wraps around on overflow) so the value stays an exact 32-bit word. Note that multiplying by a power of two is equivalent to a left shift — see Bitwise SHL.

Bitwise flows are not directly compatible with data flows. You must use integer-to-bitwise to set bitwise inlets and bitwise-to-integer to retrieve outlet values. Bitwise inputs are in hexadecimal format (0123456789ABCDEF). ie. $FA234B, $FFFF, etc. Bitwise flows are compatible with Color flows.

Settings

a

First entry value.

b

Second entry value.

out

Result.

Example

A normal product, then one whose true result exceeds 32 bits so only the low word is kept:

A B out
$0000000A $00000003 $0000001E (10 × 3 = 30)
$00010000 $00010000 $00000000 (2³² wraps)
Common Settings

info

show manual

Button. Opens the manual page of the selected object (or of its parent module for a control) in the web browser. If no page exists for this object, an error is traced in the trace panel.

For more details about information/help creation, see create-help-file.

description

Free multi-line text attached to the module, saved with the patch. It is only meant as an internal note for the patch designer: it is not displayed in the interface.

ID's

visible only in god mode, see setup-panel-tab-expert.

unique ID

Read-only, not saved. Current private numeric ID of the object, used internally to identify it (for example as the target of a bind ID).

preset ID

Read-only, not saved. Private ID used to store and recall the values of this control in presets.

recreate ID

Button. Generates a new unique ID, original ID and preset ID for the object. Use it if you experience difficulties in Polyphonic mode or if two objects share the same ID. Preset values and binds referring to the old IDs are lost.

Object Remote Address

absolute

Read-only, not saved. Absolute address of the object in the Usine objects tree, built from the workspace root. This is the address to use to reach the object from scripts, the objects panel or remote messages. Only shown for objects that are registered in the objects list. See objects-address.

local

Read-only, not saved. Address of the object relative to the current patch, valid inside that patch only. See objects-address.

user addr

Free user-defined address for the object (empty by default). When set, the object is also registered in the objects tree under this name, so it can be reached independently of its position in the workspace (the value is also reported in the mouse-over and mouse-down chunks). Changing it rebuilds the objects list. Only available on objects that support a user address. See objects-address.

See also