Settings related to remote control assignation and learn.
Button. Resets the whole remote configuration of the control to its defaults: MIDI, key, OSC, timecode, bind bus, bind control, VCA, cluster, DMX and mapping assignations are all cleared and the control is removed from the remote lists. To clear only one part, use clear bind bus or clear bind control.
ON/OFF switch, default ON. When OFF, all the remote assignations of the control (MIDI, key, OSC, timecode, DMX, binds) are ignored, even if they stay stored in the control. When ON, the assignations are processed according to active mode.
ON/OFF switch, default OFF. When ON, the received value is inverted before being applied to the control: MIDI values become 127 - value (16129 - value for pitch bend), OSC and bind values in the [0..1] range become 1 - value, relative MIDI moves go in the opposite direction and a sysex learn sends 0 instead of 127.
Delays the application of a received remote value until the next synchronisation event of the master synchro. The quantization is only applied when the master synchro is playing; otherwise the value is applied immediately. Only available on controls that can be quantized. Default none.
Determines when the remote assignations of the control are processed. Has no effect if remote active is OFF. Default always.
See binds-panel.
Button. Removes the bind bus assignation of the control: binding is emptied and the control is removed from the bind bus remote list.
Name of the bind bus the control listens to (empty = no bind). Each time the bus value changes, it is applied to the control (in the [0..1] range, scaled to the control range, after inverse and the mapping settings). On a panel, the bus enables it when the value is above 0.5; on a button, it triggers it. The control is highlighted with the color of the bus while it receives values.
Unique ID of the source control this control is bound to (empty = no bind). The source is looked up by this ID; if it no longer exists, the bind is cleared automatically. The value of the source control is copied to this control each time it changes, scaled from the source range to the target range (switches and data values follow inverse; listbox, trigger and color values are copied as they are).
Read-only. Caption of the source control identified by bind ID, refreshed automatically when the bind is processed. Also available as an outlet on modules.
Removes the bind control assignation: bind ID and bind caption are emptied and the control is removed from the bind control remote list.
Button. Arms the MIDI learn: move a control on your MIDI device and the first message received is assigned to the control (channel, control type, control num, device name and, if the device is declared as motorized in the devices panel, motorized are filled automatically).
Name of the MIDI device the assignation is restricted to. Filled during the learn when the memorize device name in learn setting of the setup panel is ON. When empty, the assignation reacts to all connected MIDI input devices; MIDI feedback (motorized) is also sent only to the device with this name unless MIDI feedback to all is ON in the setup.
Use [Ctrl+Click] to delete the name association so the MIDI learn will react with all the connected devices.
MIDI channel used for the MIDI assignation, from 1 to 16. Only messages received on this channel are taken into account.
Data number of the assigned MIDI message, from 0 to 127: note number for notes and poly aftertouch, controller number for control changes. Ignored for program change, channel aftertouch and pitch bend, which match any number.
Type of MIDI message assigned to the control (the MIDI status value is shown in parentheses).
Choose between the 3 MIDI assignation modes in Usine. Default absolute.
(value - 64) / 127, an integer fader or a listbox goes to the next or previous item, a button is triggered on each message.ON/OFF switch, default OFF. Only used together with motorized. When ON, the MIDI feedback is always sent back to the controller, including for the value just received (as required by the Mackie Control protocol to update displays, leds and fader positions). When OFF, the value just received from MIDI is not sent back, to avoid MIDI loops.
ON/OFF switch, default OFF (set automatically during the learn when the device is declared as motorized). When ON, each time the value of the control changes Usine sends the corresponding MIDI message (same channel, control type and control num) to the MIDI output devices so that motorized faders, leds or displays follow the on-screen value. The message is sent to the output device named in device name only, unless MIDI feedback to all is ON in the setup or the name is empty.
ON/OFF switch, default OFF. When ON, an incoming MIDI (or DMX, bind bus) value is ignored as long as it differs from the current position of the control by more than 4%, unless the control was already moved by the remote during the last second. Once the hardware control matches the on-screen value, the control latches on and follows it again.
For instance say you have a line fader turned all the way up on the hardware, then you move the onscreen line fader to the bottom. With soft-takeover ON, the onscreen fader will not react to the line fader until you move the line fader all the way down to match the on screen value. The control will then latch on and will be active again.
System exclusive string assigned to the control (hexadecimal bytes, filled by the MIDI learn when a sysex message is received). Each time the same sysex is received, the control is set to its maximum (or toggled, depending on the control type and midi mode); with inverse ON it is set to its minimum.
Click on this button and press a key (or a key combination ie. [ALT+E]) on your keyboard to assign it. Only available on controls that accept key learn. [Esc] cancels the learn.
Text of the key or key combination assigned to the control, as displayed in the settings (for example A or ALT+E). You can also type it by hand: in that case shortcut is 0 and the text is compared, in uppercase, with the typed character. Empty means no key assignation.
Determines how the key affects a switch. Default toggle. Only available on controls that allow changing the key mode.
Buttons are triggered and panels are enabled/disabled on each key press whatever the mode.
Numeric key code of the assigned key (0 to 65535, ex: A=65), including the modifier bits, filled automatically by the key learn. 0 means the key text is used as a user key.
Curve applied to the received value (in the [0..1] range) before it is scaled to the control range, for MIDI, DMX, bind bus and OSC in in [0..1] mode. Default linear.
x^(1/coeff); a mapping curve coeff below 1 gives an exponential-like curve, above 1 a logarithmic-like curve.The resulting curve is drawn below the settings.

Coefficient of the mapping curve, from 0.001 to 100 (logarithmic scale), default 1. Has no effect when mapping curve is linear.
Upper limit of the mapped value in the [0..1] range, default 1. The received value (after the mapping curve) is rescaled between mapping range min and mapping range max before being applied to the control range. If it is lower than mapping range min, the control stays at mapping range min.
Lower limit of the mapped value in the [0..1] range, default 0. See mapping range max.
Click on this button and use a control of your OSC device to assign it. The address of the first OSC message received is stored in OSC message and OSC tag order is reset to 1.
OSC address assigned to the control (for example /1/fader1). Each message received with exactly this address sets the control (buttons ignore messages with a 0 value, panels are enabled when the value is above 0.5). Empty means no OSC assignation.
Determines how the received OSC value is interpreted. Default real value.
Index (1 to 256, default 1) of the argument used when the OSC message carries several values at once (for example the X and Y of an XY pad): 1 uses the first argument, 2 the second, etc. Reset to 1 by the OSC learn.
Timecode position at which the control is triggered (buttons and other trigger controls). The trigger happens once, when the incoming timecode passes this position. 0 means no timecode assignation.
Timecode position at which a switch control is set to its minimum (OFF). Only checked if the timecode ON position was not reached at the same time.
Timecode position at which a switch control is set to its maximum (ON). 0 means no timecode assignation.
Name(s) of sources VCA's. One control can be controlled by several VCA at the same time so the VCA values are multiplied together.
To enter several names use comma separated string like VCA1,VCA2,VCA3. Names are converted to uppercase and trimmed when applied.
See use-vca for more info.
Name(s) of the owner cluster(s). One control can be in many clusters at the same time, but be aware that you could have conflicts (different value sent at the same time).
To enter several names use comma separated string like CLUSTER1,CLUSTER2,CLUSTER3.
See use-clusters for more info.
Art-Net universe number (0 to 32767, default 0) the control listens to. Only DMX packets received on this universe are taken into account.
DMX channel (1 to 512) assigned to the control in the universe, 0 (default) means no DMX assignation. The received byte (0 to 255) is scaled to [0..1] then applied: faders follow the value (through the mapping settings and soft take over), switches and panels are ON when the value is above or equal to 0.5, buttons are triggered when the value rises above 0.5, listboxes select the item proportionally.
version 7.0.250121