This module allows to represent in 2D a database made with the DatabaseCreation module. Using a cursor, the module will output a list of the nearest sample paths inside the radius and a coefficient. Moreover, the module resynthesize an audio texture corresponding to an average of the samples in the cursor. See database-creation
Path to the database file.
Reload the database. Useful if an error occurs or when overwriting the current database with a new one.
Horizontal axis of the 2D representation.
Vertical axis of the 2D representation.
Create a new representation according to the specified dimensions.
Maximum number of closest samples. This doesn't count samples in the release phase, i.e samples not in the radius of the circle anymore, waiting for their coefficient to get to 0 before getting out of the list.
List of the selected closest samples. Maximum size of 40.
Coefficients of the samples in the samples list with matching indexes.
Duration of the increase of the coefficients value.
Duration of the decrease of the coefficients value.
Switch corresponding to the state of the resynthesis.
Audio outputs of the resynthesis.
Switch corresponding to the state of the cursor.
Coordinate value of the cursor along the horizontal axis of the cursor.
Coordinate value of the cursor along the vertical axis of the cursor.
Radius around the cursor in which closest samples are searched.
Radius of the points in the map.
Allows you to adjust the spreading of the representation on the horizontal axis.
Allows you to adjust the spreading of the representation on the vertical axis.
By default coefficients are normalized. If unchecked, the coefficients will be based on the distance to the radius (maximum values of the coefficients at the center).
Button. Opens the manual page of the selected object (or of its parent module for a control) in the web browser. If no page exists for this object, an error is traced in the trace panel.
For more details about information/help creation, see create-help-file.
Free multi-line text attached to the module, saved with the patch. It is only meant as an internal note for the patch designer: it is not displayed in the interface.
visible only in god mode, see setup-panel-tab-expert.
Read-only, not saved. Current private numeric ID of the object, used internally to identify it (for example as the target of a bind ID).
Read-only, not saved. Private ID used to store and recall the values of this control in presets.
Button. Generates a new unique ID, original ID and preset ID for the object. Use it if you experience difficulties in Polyphonic mode or if two objects share the same ID. Preset values and binds referring to the old IDs are lost.
Read-only, not saved. Absolute address of the object in the Usine objects tree, built from the workspace root. This is the address to use to reach the object from scripts, the objects panel or remote messages. Only shown for objects that are registered in the objects list. See objects-address.
Read-only, not saved. Address of the object relative to the current patch, valid inside that patch only. See objects-address.
Free user-defined address for the object (empty by default). When set, the object is also registered in the objects tree under this name, so it can be reached independently of its position in the workspace (the value is also reported in the mouse-over and mouse-down chunks). Changing it rebuilds the objects list. Only available on objects that support a user address. See objects-address.